Commercial PAC Series
HEAVY DUTY
AIR-CONDITIONERS

The PAC range from Mitsubishi Heavy Industries (MHI) is ideal for air conditioning offices, shops, restaurants, and bars, as well as other commercial use. The versatility of the PAC range, offers you a wide selection of models for your installation needs. Our PAC systems are available with a wide range of indoor units, with capacities ranging from 5 - 24 kW.

Single Splits
Type Capacity Range (Nominal Cooling Capacity)
Micro Inverter
HP 2.0 3.0 4.0 6.0 4.0 6.0 10.0
kW 5.0 7.1 10.0 14.0 10.0 14.0 24.0
Btu/h 17,100 24,200 34,100 47,800 34,100 47,800 81,300
kcal/h 4,300 6,100 8,600 12,040 8,600 12,040 20,640
CEILING CASSETTE
P.26
4way
FDT
Set 1phase FDT50ZSXVG FDT71VNXVG FDT100VNXVG FDT140VNXVG FDT100VNVG FDT140VNVG
FDT71VNPVF1 FDT90VNPVF1
3phase FDT100VSVG FDT140VSVG
Indoor unit FDT50VG FDT71VG FDT100VG FDT140VG FDT100VG FDT140VG
Outdoor unit 1phase SRC50ZSX-S FDC71VNX FDC100VNX FDC140VNX FDC100VN
3phase FDC100VS FDC140VS
                   
                   
                   
DUCT CONNECTED
P.30
High Static
pressure
FDU
Set 1phase FDU71VNXVF FDU100VNXVF FDU140VNXVF FDU100VNVF FDU140VNVF
3phase FDU100VSVF FDU140VSVF FDU250VSAVG
Indoor unit FDU71VF FDU100VF FDU140VF FDU100VF FDU140VF FDU250VG
Outdoor unit 1phase FDC71VNX FDC100VNX FDC140VNX FDC100VN
3phase FDC100VS FDC140VS FDC250VSA
P.34
Low/Middle
Static pressure
FDUM
Set 1phase FDUM50ZSXVF FDUM71VNXVF FDUM100VNXVF FDUM140VNXVF FDUM100VNVF FDUM140VNVF
3phase FDUM100VSVF FDUM140VSVF
Indoor unit FDUM50VF FDUM71VF FDUM100VF FDUM140VF FDUM100VF1 FDUM140VF
Outdoor unit 1phase SRC50ZSX-S FDC71VNX FDC100VNX FDC140VNX FDC100VN
3phase FDC100VS FDC140VS
    CEILING
SUSPENDED
P.38
FDE
Set 3phase FDE100VSVG FDE140VSVG
Indoor unit FDE100VG FDE140VG
Outdoor unit 3phase FDC100VS FDC140VS
FLOOR STANDING
P.40
FDF
Set 3phase FDF100VSVD FDF140VSVD
Indoor unit FDF100VD FDF140VD
Outdoor unit 3phase FDC100VS FDC140VS

All outdoor units(Hyper, Micro, Standard)


MULTI SYSTEM

Twin / Triple / Double Twin Multi System

Up to Four indoor units can be connected to a single outdoor unit
and simultaneously operated with a single remote control.
By referring to the following table for applicable indoor units,
select the same models and capacities.

Applicable indoor units

Model
Capacity Combination
40 50 60 71 100 125 Twin Triple Double Twin
4way
FDT

Low/Middle Static pressure
FDUM
   
Ceiling Suspended
FDE
Floor Standing
FDF
Combination of indoor units
Outdoor Unit Micro Inverter
FDC71VNX FDC100VNX FDC140VNX FDC140VNX FDC140VSX FDC100VN
FDC100VS
FDC125VN FDC125VS FDC140VS FDC200VSA FDC250VSA
Twin 40 + 40 50 + 50 60 + 60 71 + 71 50 + 50 60 + 60 71 + 71 100 + 100 125 + 125
Triple 50 + 50 + 50 50 + 50 + 50 71 + 71 + 71
Double Twin 50+50+50+50 60+60+60+60
Decision of piping specification Diagrams below show the application as samples. For further information, refer to TECHNICAL MANUAL.
(Example)
Models FDC100~140VNA/VSA
[Branch pipe set : DIS-WA1G]
Indoor unit combinations Liquid pipe Gas pipe
Main pipe Branch pipe Main pipe Branch pipe
FDC100 50+50 ø9.52Xt0.8 ø9.52Xt0.8 ø15.88Xt1.0 ø12.7Xt0.8
FDC140 71+71 ø15.88Xt1.0
FDC140 71+71
Note (1)When 50 models of indoor units are applied to this combination, the reducer 3 supplied with the branch piping set should be used in order to reduce the liquid piping size from ø9.52mm to ø6.35mm at indoor unit side (flare connection). Accordingly be sure to select the liquid piping size ø9.52mm from branch to indoor unit. (2)The reducer 4 is for FDC100 models only.
Chart of shapes of branch piping parts (DIS-WA1G) Gas pipe Symbol Liquid pipe Symbol Reducer Symbol Reducer Symbol
Notes (1)Symbol 1 to 4 in the drawing shows the symbols of branch piping parts in the chart respectively.
(2)Branch piping should always be arranged to have level or perpendicular position.
The branch piping (both gas and liquid lines) should always be arranged to have a level or perpendicular position.
2-Way Branch Floor     Floor       Floor
Mount--sections level with the floor. Mount--sections perpendicular to the floor.  
         
         
3-Way Branch Floor       Floor       Floor

V MULTI SYSTEM

Ideal for the installation in large area and L-shaped rooms, the V Multi System has an extensive degree of flexibility in the selection of indoor units.Specifically, the selection of indoor units with different capacities in different types can be made.

Applicable indoor units
Model
Capacity
50 71 100
4way
FDT
Ceiling Suspended
FDE
Combination of indoor units
Outdoor Unit Micro Inverter
FDC100VNX FDC140VNX FDC100VN
FDC100VS
FDC140VS FDC250VSA
Twin 50 + 50 71 + 71 50 + 50 71 + 71
Triple 50 + 50 + 50 50 + 50 + 50 71 + 71 + 100
Double Twin
Decision of piping specification Diagrams below show the application as samples. For further information, refer to TECHNICAL MANUAL.
The indoor_outdoor piping length differences among indoor units are less than 3m.
Model FDC140VS
[Branch pipe set : DIS-TA1G]
Indoor unit combinations Liquid pipe Gas pipe
Main pipe Branch pipe Main pipe Branch pipe
FDC140 50+50+50 ø9.52Xt0.8 ø9.52Xt0.8 ø15.88Xt1.0 ø12.7Xt0.8
Note (1) The reducer 3 supplied with the branch piping set should be used in order to reduce the liquid piping size from ø9.52mm to ø6.35mm at indoor unit side (flare connection). Accordingly be sure to select the liquid piping size ø9.52mm from branch to indoor unit.
Chart of shapes of branch piping parts (DIS-TA1G) Gas pipe Symbol Liquid pipe Symbol Reducer Symbol
Notes (1)Symbol 1 to 3 in the drawing shows the symbols of branch piping parts in the chart respectively.
(2)Branch piping should always be arranged to have level or perpendicular position.